• Dancryl
  • 635-0XX Dancryl Acrylic Post-Cat Clear TC
  • Product Codes:

    635-015 15° Matte
    635-035 35° Satin
    635-090 90° High Gloss

  • Surface Preparation:

    Wood substrate should be sanded with 120, 150 or 180 grit paper prior to staining or coating. Sealers should be sanded with 280/320 grit stearated paper prior to topcoating. Appropriate sealers are self seal or catalyzed 401 line vinyl sealer. When recoating, the sealer or previous coat must be sanded and the next coat applied within eight hours. Stain systems under acid containing coatings should be acid stable. Dancryl can not be used on metal, old oil or cellulose lacquers.

  • General Information:

    Agitate material before use. Always mix Dancryl while adding hardener and reducers in the recommended mixing ratios. Dancryl must be agitated thoroughly at all times to ensure product consistency and consistent gloss.
    Apply at 3-5 mils wet on sanded substrate. Further coats may be applied after complete drying followed by sanding with 280/320 grit stearated paper.
    Contact with metal surfaces should be avoided.
    Maximum film build of Dancryl should not exceed 4 mils dry. Maximum film build of total coating system must not exceed 4 mils dry.

    To obtain a complete cure, the system should be applied at an ambient temperature above 18ºC and a relative humidity below 65%. When drying, this product is not to be exposed to ammonia vapors. Finished surfaces must not be cleaned with ammonia containing products.

    This product could be used as a self seal or over catalyzed vinyl sealer 401-004.

  • PDF Name: CA-PIS_635-0XX_Dancryl_Acrylic_Post-Cat_Clear_TC
  • Tack Free Time: 20 minutes
  • Files: CA-PIS_635-0XX_Dancryl_Acrylic_Post-Cat_Clear_TC.pdf
  • Dry to Sand : 6 hours
  • Dry to Stack: Overnight
  • Tack Free Time: Flash off before entering oven
  • Dry to Sand: 2 hours
  • VOC less exempt g/l: 582
  • VOC g/l: 582
  • Dry to Stack: 3 hours
  • Note: N/A
  • Note:

    See individual compliance sheets for specific data

  • spec_description:

    Dancryl is a two component, acrylic lacquer designed for all types of wood for interior use. It provides a smooth, hard wearing surface that is resistant to alcohol, water, grease and usual household chemicals. Dancryl is especially suited for topcoating light coloured basecoats due to its good light stability and water white appearance.

  • spec_uses:

    Dancryl is used on interior wood when clarity and light stability are very important.

  • Suggested Uses: Spray
  • Mixing Ratio:

    8% with 999-017 by volume

  • Pot Life:

    8 hours

  • Application Viscosity:

    Zahn #2 signature cup 20-25 seconds

  • Reducer: 121-8020 or 121-803
  • Retarder: 800-5328 EEP
  • Clean-up Solvent: Lacquer Thinner
  • Recommended Wet Film: 3-5 wet mils
  • Coverage:

    13 m2/l (145 pi2/l) at 1 mil dry and at 100% efficiency. Coverage will vary depending on method of application or coating thickness.

  • Note application:

    N/A

  • Viscosity:

    Zahn #2 signature cup 40 sec at 25°C

  • Flash Point: 14°C (57°F)
  • Density (lb/gal): 0.95
  • Solid (% by weight): 39%
  • Solid (% by volume): 34%
  • Shelf Life (months): 12

Dancryl

635-0XX Dancryl Acrylic Post-Cat Clear TC

Find distributor Trouver un distributeur

spec_description:

Dancryl is a two component, acrylic lacquer designed for all types of wood for interior use. It provides a smooth, hard wearing surface that is resistant to alcohol, water, grease and usual household chemicals. Dancryl is especially suited for topcoating light coloured basecoats due to its good light stability and water white appearance.

Read more
Product codeCodes de produit
Product Codes:

635-015 15° Matte
635-035 35° Satin
635-090 90° High Gloss


Product information

  • Viscosity:

    Zahn #2 signature cup 40 sec at 25°C

  • Flash Point: 14°C (57°F)
  • Density (lb/gal): 0.95
  • Solid (% by weight): 39%
  • Solid (% by volume): 34%
  • Shelf Life (months): 12

Download product information sheets

fas fa-download

These products are designed for industrial use only. AkzoNobel views safety as a top priority. Please refer to Material Safety Data Sheet for information on the safe use of this product.

Dry times are greatly affected by film build, porosity of substrate, air movement as well as heat and humidity. Temperatures are based on actual board temperature. This may vary depending on length of time for boards to reach these temperatures. Minimum curing temperatures of 64°F/18°C must be maintained throughout the curing cycle to achieve the film integrity as stated in product features.

Image

Recommanded for interior woodwork

OmniBuild Pro Conversion Varnish Primer Surfacer is recommended for interior woodwork on solid wood and MDF.

Recommandé pour les boiseries intérieures

OmniBuild Pro, apprêt à catalyser est recommandé pour les travaux de menuiserie intérieure sur bois massif et MDF.

View our ranges

Our extensive wood coatings expertise covers all technologies. From pre-catalyzed to waterborne, nitrocellulose to polyurethane, we deliver a wide range of top-performing products for your business.

Need help? Contact our team of wood coating experts.

Contact us

©Copyright 2026 AkzoNobel. All Rights Reserved. Chemcraft is a registered trademark of Akzo Nobel Coatings Inc.© Droit d’auteur 2026 Tous droits réservés. Chemcraft est une marque déposée d’AkzoNobel Coatings Inc.

AkzoNobel